← Back to Help Center

Connecting a feed mixer to feedlot records

What to collect from mixer hardware, how to reconcile it with GanFarm deliveries and the validation needed before automation.

Current scope versus future integrations

GanFarm records rations, pen occupancy and manual deliveries. It also previews and imports CSV/TXT exported mixer logs, without connecting directly to the physical device.

Automatic mixer integration is not enabled. Manufacturers differ in file exports and protocols; each exact model and firmware must be tested.

Minimum reliable integration fields

A reliable integration needs a unique operation identifier, device, time, ration, destination pen, planned and actual kilograms. Multiple pen drops must remain distinct.

Ingredient loading weights, operator, tolerances, mixing times and alarms add context. Loading weight is not delivered weight; retries must not duplicate events.

Prepare a physical-device pilot

Before developing a connector request sample exports and protocol/interface specifications. Do not send unknown commands to operating machinery.

  1. Record manufacturer, exact model, serial, firmware and available transport.
  2. Export a test day with partial loading, two drops and one correction.
  3. Map columns to pen, ration, quantity, timestamp and reference.
  4. Test totals, rounding, units, timezone and deduplication with an operator.
  5. Enable automation only after real-data acceptance tests and a rollback plan.

Mixer, chute, scale and RFID are different data sources

The mixer records feed delivery; chute devices identify and weigh animals. Existing RFID sessions still require model-specific validation. Combining sources helps analysis but does not measure individual feed intake.

If offline, retain approved local logs and reconcile them on reconnect. Future adapter offline capabilities require their own testing.